Abstract

Brain Electrical Capacitance Volume Tomography (ECVT) has been developing as an alternative non-invasive brain imaging method. In this study, brain ECVT consisting of two channels, namely a capacitance sensor, is investigated. As a comparison, EEG sensor is used to measure brain activity simultaneously with the brain ECVT. Brain activity measurements were carried out at the pre-frontal lobe of Fp1 and Fp2 locations. The resulting signal was processed by filtering method and Power Spectral Density (PSD). The result of signal analysis shows that the measurement between EEG and ECVT shows the same activity of the two modalities.

Keywords: ECVT, Brain, EEG, PSD, Capacitance

Downloads

Download data is not yet available.

References

  1. Gallagher, A., Lassonde, M., Bastien, D., Vannasing, P., Lesage, F., Grova, C., Bouthillier, A., Carmant, L., Lepore, F., Béland, R., & Nguyen, D. K. (2008). Non-invasive pre-surgical investigation of a 10 year-old epileptic boy using simultaneous EEG-NIRS. Seizure. doi:10.1016/j.seizure.2008.01.009
  2. Glover, G. H. (2011). Overview of functional magnetic resonance imaging. Neurosurgery Clinics of North America. doi:10.1016/j.nec.2010.11.001
  3. Huang, S. M., Plaskowski, A. B., Xie, C. G., & Beck, M. S. (1989). Tomographic imaging of two-component flow using capacitance sensors. Journal of Physics E: Scientific Instruments. doi:10.1088/0022-3735/22/3/009
  4. Ihsan, M. F., Edison, R. E., Pratama, S. H., Saputra, A., Rohmadi, R., & Taruno, W. P. (2020). Real-Time Measurement of Integrated Multichannel EEG-ECVT in Pre-Frontal Lobe. European Journal of Molecular & Clinical Medicine, 7(10), 1343–1350.
  5. Maharani, R., Edison, R. E., Ihsan, M. F., & Taruno, W. P. (2020). Average Subtraction Method for Image Reconstruction of Brain using ECVT for Tumor Detection. International Journal of Technology. doi:10.14716/ijtech.v11i5.4325
  6. Rizki, E. E., Uga, M., Dan, I., Dan, H., Tsuzuki, D., Yokota, H., Oguro, K., & Watanabe, E. (2015). Determination of epileptic focus side in mesial temporal lobe epilepsy using long-term noninvasive fNIRS/EEG monitoring for presurgical evaluation. Neurophotonics. doi:10.1117/1.nph.2.2.025003
  7. Wang, F., Marashdeh, Q., Fan, L. S., & Warsito, W. (2010). Electrical capacitance volume tomography: Design and applications. Sensors. doi:10.3390/s100301890
  8. Warwick, J. M. (2004). Imaging of brain function using SPECT. Metabolic Brain Disease. doi:10.1023/B:MEBR.0000027422.48744.a3
 How to Cite
Edison, R. E., Rohmadi, R., Pratama, S. H., Ihsan, M. F., Saputra, A., & Purwo Taruno, W. (2021). Design of Brain Activity Measurement for Brain ECVT Data Acquisition System. International Journal of Innovative Research in Medical Science, 6(10), 630–634. https://doi.org/10.23958/ijirms/vol06-i10/1223

Copyrights & License